144-Fiber OM4 MTP/MPO Trunk Cable, MTP-12 (x12) to MTP-12 (x12), UPC, Type C
The 144-Fiber OM4 MTP/MPO Trunk Cable combines twelve 12-fiber MTP/MPO UPC connectors at each end with OM4 50/125μm multimode fiber for high-density backbone connectivity. Its Type C polarity, compact micro-core construction, and low-loss connector performance make it suitable for modern data center and structured fiber cabling systems.
-
Description
-
Specification
-
Features
-
Application
-
Custom Service
-
FAQ
The 144-Fiber OM4 MTP/MPO Trunk Cable is a high-density multimode backbone assembly designed for data centers, structured cabling systems, and high-capacity short-reach optical networks. Featuring twelve 12-fiber MTP/MPO connectors at each end, the cable provides 144 optical fibers within a compact micro-core construction, allowing large numbers of fiber connections to be consolidated into a single organized trunk. Built with OM4 50/125μm multimode fiber and MTP® Elite® UPC connectors, it provides high-bandwidth connectivity while helping reduce cable congestion and optimize rack and cable pathway space.
The cable uses Type C polarity, which reverses fiber pairs between the two ends for compatible duplex and parallel-optics architectures. Factory-terminated MTP/MPO connectors provide consistent optical performance and enable rapid deployment without field connector termination. With a 17.5 mm cable diameter and low-loss connector performance, this trunk assembly is suitable for high-density connections between MTP/MPO cassettes, adapter modules, fiber distribution systems, and network equipment.| Total Fiber Count | 144 Fibers |
|---|---|
| Fiber Configuration | 12 × 12 Fibers |
| Fiber Mode | Multimode |
| Fiber Type | OM4 |
| Fiber Core / Cladding | 50/125μm |
| Cable Construction | Micro-Core Fiber Cable |
| Cable Application | Internal / Indoor Use |
| Connector A | 12 × MTP Elite 12-Fiber UPC |
| Connector B | 12 × MTP Elite 12-Fiber UPC |
| Connector Type | MTP / MPO |
| Connector Polish | UPC |
| Connector Fiber Count | 12 Fibers |
| Polarity | Type C |
| Connector Insertion Loss | Typical <0.12dB |
| Maximum Insertion Loss | ≤0.25dB for 97% of channels |
| Connector Return Loss | ≥25dB |
| Cable Diameter | Approx. 17.5mm |
| Cable Length | Customizable |
| Jacket / Fire Rating | Cca-s1b | d0 | a1 |
| Operating Environment | Indoor |
- 144-fiber OM4 multimode MTP/MPO trunk cable
- Twelve 12-fiber MTP/MPO connectors at each end
- OM4 50/125μm laser-optimized multimode fiber
- MTP® Elite® 12-fiber UPC connectors
- Type C polarity for cross-pair fiber mapping
- Compact micro-core cable construction
- Approx. 17.5 mm cable diameter
- Typical connector insertion loss below 0.12dB
- 97% of channels achieve insertion loss of ≤0.25dB
- Connector return loss of ≥25dB
- High fiber density for efficient backbone cabling
- Factory-terminated for fast and consistent installation
- Suitable for MTP/MPO cassette and adapter-based systems
- Helps simplify cable routing and high-density cable management
- Designed for short-reach high-speed multimode networks
- Cca-s1b,d0,a1 rated cable construction
- High-density data center backbone cabling
- MTP/MPO structured cabling systems
- Rack-to-rack fiber connections
- MTP/MPO cassette and adapter module connections
- Fiber distribution and cross-connect systems
- High-speed multimode Ethernet networks
- Parallel-optics network infrastructure
- Server-to-switch and switch-to-switch interconnects
- Enterprise and cloud data centers
- High-density network cabinets
- Telecommunications and equipment rooms
OEM and customized MTP/MPO trunk cable assemblies are available for data center and structured cabling projects. Cable length, fiber count, fiber type, connector configuration, connector polish, polarity, jacket construction, labeling, and packaging can be customized according to project requirements.
Alternative MTP/MPO connector configurations and fiber counts can also be supplied for specific network architectures. Custom cable constructions can be developed for different installation environments, equipment interfaces, and high-density distribution requirements.
What does MTP-12 (x12) mean in this 144-fiber cable?
The designation means that each end contains twelve MTP/MPO connectors, with each connector carrying 12 fibers. Twelve 12-fiber connectors provide a total of 144 optical fibers, making the assembly a Base-12 high-density trunk configuration.
What is the purpose of Type C polarity in this assembly?
Type C polarity reverses the fiber pairs between the two ends of the cable. This is different from Type A, which maintains the same fiber position, and Type B, which reverses the complete fiber sequence. Type C is used where pair-level reversal is required by the specific duplex or parallel-optics link architecture.
Why is OM4 preferred for high-density data center cabling?
OM4 is a laser-optimized multimode fiber with higher bandwidth capability than earlier multimode grades such as OM3. It is well suited to short-reach, high-speed data center applications and allows high-bandwidth optical links to be deployed over relatively compact distances using multimode transceivers.
Does the 0.25dB specification apply to every connector?
The original specification states that 97% of channels achieve an insertion loss of ≤0.25dB, while the typical connector insertion loss is below 0.12dB. Therefore, 0.25dB should be treated as the specified performance level for 97% of channels rather than a guaranteed value for every individual channel.
Why is the cable diameter larger than a 48-fiber trunk?
The 144-fiber assembly contains three times as many optical fibers as a 48-fiber trunk, so its overall cable construction naturally requires more internal space. The approximately 17.5 mm diameter provides a practical balance between high fiber capacity, mechanical protection, and cable routing requirements.
Can this cable be used with MTP/MPO cassettes from other manufacturers?
Yes, the MTP/MPO interface is based on standardized multi-fiber connector technology and can be used with compatible cassettes and adapter modules from other manufacturers. However, connector performance, polarity, gender, and key orientation should be verified before deployment to ensure compatibility with the complete link.
Related products
- MPMPB-R144S12YL02
144-Fiber OS2 Single Mode MTP/MPO Trunk Cable, 12×MTP/MPO-12 APC Female to Female, Type B
- MPOMPOB-R144S8MG01
144-Fiber OM4 MTP/MPO Trunk Cable, 12×MTP/MPO-12 UPC Female to Female, Type B
- MTPMTP-R96S8YL02
96-Fiber MTP/MPO Single Mode Trunk Cable, 8×MTP/MPO to 8×MTP/MPO OS2 Fiber Patch Cord, Type A/B/C
- MTPMTP-R96S12MG01
96-Fiber MTP/MPO Trunk Cable 8×12-Fiber OM4 Multimode Plenum PVC Male-to-Female
- MPMPC-R96S12YL10
MTP-12 (x8) to MTP-12 (x8) 96-Fiber Single Mode G.657.A1 MTP Trunk Cable, APC, Type C